Get expert advice and tailored solutions for your research needs

In this paper we demonstrate an application of the micro corona‐Kelvin metrology to monitoring of the electrical properties of silicon oxynitrides prepared with a plasma nitridation process currently used for advanced gate dielectrics. Key measurement parameters to be discussed are: dielectric capacitance equivalent thickness (CET), dielectric voltage in valence band tunneling range (VB), interface trapped charge (Qit) and flatband voltage.